Best High Humidity Transmitter HG808-H – Stable Long-Term Performance in Over 95% RH High Moisture Environments

HENGKO HG808 SERIES / HIGH-HUMIDITY MONITORING

HG808-H High-Humidity Temperature & Humidity Transmitter

Designed for Stable Monitoring in High-Moisture Industrial Environments

Monitor temperature, relative humidity and calculated dew point in demanding industrial environments. The HENGKO HG808-H is designed for high-humidity applications, with multiple probe configurations, RS485 Modbus RTU communication and selectable analog outputs.

High-Humidity Applications RS485 Modbus RTU Optional Display

View Specifications Request a Quote

RH MEASUREMENT 0–100% RH Specified measurement range RH ACCURACY ±2% RH At 20°C, 10–90% RH COMMUNICATION RS485 Modbus RTU

High-humidity application suitability and the allowable duration above 95% RH require confirmation for the selected probe and operating conditions. The supplied specifications recommend operation below 95% RH in non-condensing conditions.

01 / THE MEASUREMENT CHALLENGE

Why Is Humidity Measurement Difficult Near Saturation?

In high-moisture production environments, temperature changes can push relative humidity close to saturation. Moisture accumulation, contamination and repeated wet-dry cycles may affect sensor response and measurement stability.

Reliable monitoring requires more than a wide measurement range. Engineers must consider sensor protection, probe placement, condensation exposure, calibration and the long-term operating conditions of the complete transmitter assembly.

The HG808-H Application Focus

The HG808-H is positioned for demanding high-humidity monitoring applications. For continuous operation at 95–98% RH, or wherever condensation may occur, request confirmation of the applicable probe configuration and verified performance limits.

02 / PRODUCT CAPABILITIES

Built for Industrial Humidity Monitoring and Control Integration

01 / SENSOR PERFORMANCE

Temperature & RH Measurement

Specified RH accuracy of ±2% RH at 20°C and 10–90% RH, with temperature accuracy of ±0.1°C at 20°C.

02 / DIGITAL DATA

Dew Point & PPM Outputs

RS485 output provides temperature, relative humidity, calculated dew point and PPM data for compatible monitoring systems.

03 / SYSTEM INTEGRATION

Digital & Analog Interfaces

RS485 Modbus RTU and selectable analog output options support integration with suitable PLC, DCS and SCADA equipment.

04 / PROBE PROTECTION

Industrial Probe Construction

Metal probe configurations and protective filter options help adapt the measurement assembly to different installation conditions.

05 / ELECTRICAL DESIGN

Circuit Protection

The source product information lists ESD and reverse-polarity protection for industrial installations.

06 / CONFIGURATION

Display & Probe Options

Choose configurations with or without a local display and review the available probe arrangements for your equipment.

03 / PROBE SELECTION

Select the Right Probe for Your Installation

HG808 series probe configurations are intended for different mounting arrangements, including remote or split-type installations and pipeline applications. Select the probe according to the measurement location, available installation space and environmental exposure.

For high-humidity applications, probe position is especially important. Avoid locations where water can continuously collect on the sensing element unless the specific configuration is qualified for that condition.

Probe codes listed in the supplied specifications

Split-type: 0A / 0B and 6A / 6B. Pipeline: 3A / 3B and 5A / 5B. The original page also references a wider 12-probe HG808 family; verify which configurations are offered specifically for HG808-H.

04 / INDUSTRIAL APPLICATIONS

High-Humidity Monitoring Applications

The HG808-H can be considered for industrial environments where moisture levels are elevated and temperature-humidity monitoring supports process consistency or equipment protection.

Food & Beverage Processing

Monitor temperature and humidity in compatible food-processing rooms, humid production areas and moisture-sensitive operations. Confirm hygiene and cleaning requirements separately.

Fermentation & Bioprocess Environments

Support humidity monitoring in suitable fermentation rooms and controlled production environments. Direct exposure to corrosive gases or aggressive cleaning agents requires compatibility review.

Industrial Drying & Humidification

Measure conditions in compatible drying and humidification processes within the verified temperature and humidity limits of the selected probe assembly.

Environmental Test Chambers

Provide temperature and RH data for suitable controlled-humidity test environments. Repeated condensation and extreme cycling must be evaluated before selection.

Pharmaceutical Production Areas

Support environmental monitoring in compatible manufacturing spaces. Any regulated or validated application requires project-specific documentation and qualification.

05 / PRODUCT OVERVIEW

Explore the HG808 Industrial Transmitter Series

Watch the original product video to learn more about the HG808 transmitter family and available hardware configurations.

06 / TECHNICAL DATA

HG808-H Technical Specifications

The following values are based on the supplied HG808-H specification table. Confirm the selected probe configuration and its applicable operating limits before ordering.

Parameter Specification
Temperature Measurement Range −40 to +100°C
Humidity Measurement Range 0–100% RH; source recommends below 95% RH
Temperature Accuracy ±0.1°C at 20°C
Humidity Accuracy ±2% RH at 20°C, 10–90% RH
Power Supply 10–28 V DC
Power Consumption Less than 0.5 W
Analog Output Options 4–20 mA / 0–5 V / 0–10 V; select one type
RS485 Output Temperature, RH, dew point and PPM
Communication Protocol Modbus RTU
Baud Rate 1200 / 2400 / 4800 / 9600 / 19200 / 115200 bps; default 9600
Serial Format 8 data bits, 1 stop bit, no parity
Resolution Options 0.01 / 0.1°C; 0.01 / 0.1% RH
Fastest Acquisition Interval 1 second
Pressure Rating 16 bar, as listed; confirm applicable probe configuration
Working Environment −20 to +60°C, 0–95% RH, non-condensing

Measurement range is not the same as the permissible continuous operating environment. The original marketing text also states −40 to +190°C and continuous 95–98% RH capability; these claims require technical reconciliation with the datasheet.

07 / CONTROL SYSTEM INTEGRATION

Connect HG808-H to PLC, SCADA and Monitoring Systems

HG808-H supports RS485 digital communication and analog output configurations. Choose the signal type according to your controller input and the required measurement variables.

RS485 Modbus RTU

Read temperature, humidity, dew point and PPM values through a compatible digital communication interface.

Analog Signal Options

Select 4–20 mA, 0–5 V or 0–10 V output according to the ordering configuration and controller requirements.

4–20 mA Wiring Reference

0–10 V Wiring Reference

Wiring diagrams are from the original HG808 family page. Confirm the exact pinout, output configuration and power requirements for your ordered HG808-H model before installation.

08 / MODEL SELECTION

HG808-H Models With and Without Display

Choose a display-equipped model for local viewing or a non-display configuration for remote data acquisition. Review the original ordering charts for the available probe and signal combinations.

Models With Local Display

Models Without Local Display

Confirm the final model code, probe type, output signal and high-humidity operating conditions with HENGKO before placing an order.

09 / TECHNICAL FAQ

Frequently Asked Questions About High-Humidity Transmitters

Can HG808-H operate continuously above 95% RH?

The product description targets high-moisture environments up to 98% RH, but the supplied specification table recommends below 95% RH and lists non-condensing working conditions. Confirm continuous exposure limits and supporting test data for your selected configuration.

Is a high-humidity transmitter the same as a condensation-proof transmitter?

No. High relative humidity does not necessarily mean liquid water is present on the sensor. Condensing conditions require separate evaluation of sensor protection, recovery and measurement performance.

Does HG808-H support Modbus RTU?

Yes. The source specifications list RS485 Modbus RTU, with configurable baud rates including 9600 and 19200 bps.

Can the transmitter calculate dew point?

The source lists calculated dew point as an RS485 output. Dew point accuracy depends on the underlying temperature and humidity measurements and the calculation method.

What is the maximum operating temperature?

The supplied datasheet lists a temperature measurement range of −40 to +100°C and a working environment of −20 to +60°C. The higher temperature claim elsewhere on the original page requires verification for a specific probe assembly.

What information should I provide for transmitter selection?

Provide the expected RH range, whether condensation occurs, process and ambient temperatures, mounting location, pressure, required output, probe length and estimated order quantity.

HENGKO / HIGH-HUMIDITY SENSOR SOLUTIONS

Need Reliable Humidity Monitoring for a High-Moisture Process?

Share your application conditions with HENGKO to review the suitable HG808-H configuration, probe design and available output options.

Include these details in your inquiry:

Operating RH and temperature range, condensation exposure, process pressure, installation drawing, probe length, RS485 or analog output requirements, and order quantity.

Request HG808-H Technical Support & Quote

Email: ka@hengko.com