Designed for Stable Monitoring in High-Moisture Industrial Environments
Monitor temperature, relative humidity and calculated dew point in demanding industrial environments. The HENGKO HG808-H is designed for high-humidity applications, with multiple probe configurations, RS485 Modbus RTU communication and selectable analog outputs.
High-Humidity Applications RS485 Modbus RTU Optional DisplayView Specifications Request a Quote
RH MEASUREMENT 0–100% RH Specified measurement range RH ACCURACY ±2% RH At 20°C, 10–90% RH COMMUNICATION RS485 Modbus RTU
High-humidity application suitability and the allowable duration above 95% RH require confirmation for the selected probe and operating conditions. The supplied specifications recommend operation below 95% RH in non-condensing conditions.
01 / THE MEASUREMENT CHALLENGEIn high-moisture production environments, temperature changes can push relative humidity close to saturation. Moisture accumulation, contamination and repeated wet-dry cycles may affect sensor response and measurement stability.
Reliable monitoring requires more than a wide measurement range. Engineers must consider sensor protection, probe placement, condensation exposure, calibration and the long-term operating conditions of the complete transmitter assembly.
The HG808-H Application FocusThe HG808-H is positioned for demanding high-humidity monitoring applications. For continuous operation at 95–98% RH, or wherever condensation may occur, request confirmation of the applicable probe configuration and verified performance limits.
02 / PRODUCT CAPABILITIESSpecified RH accuracy of ±2% RH at 20°C and 10–90% RH, with temperature accuracy of ±0.1°C at 20°C.
02 / DIGITAL DATARS485 output provides temperature, relative humidity, calculated dew point and PPM data for compatible monitoring systems.
03 / SYSTEM INTEGRATIONRS485 Modbus RTU and selectable analog output options support integration with suitable PLC, DCS and SCADA equipment.
04 / PROBE PROTECTIONMetal probe configurations and protective filter options help adapt the measurement assembly to different installation conditions.
05 / ELECTRICAL DESIGNThe source product information lists ESD and reverse-polarity protection for industrial installations.
06 / CONFIGURATIONChoose configurations with or without a local display and review the available probe arrangements for your equipment.
03 / PROBE SELECTIONHG808 series probe configurations are intended for different mounting arrangements, including remote or split-type installations and pipeline applications. Select the probe according to the measurement location, available installation space and environmental exposure.
For high-humidity applications, probe position is especially important. Avoid locations where water can continuously collect on the sensing element unless the specific configuration is qualified for that condition.
Probe codes listed in the supplied specificationsSplit-type: 0A / 0B and 6A / 6B. Pipeline: 3A / 3B and 5A / 5B. The original page also references a wider 12-probe HG808 family; verify which configurations are offered specifically for HG808-H.
04 / INDUSTRIAL APPLICATIONSThe HG808-H can be considered for industrial environments where moisture levels are elevated and temperature-humidity monitoring supports process consistency or equipment protection.
Monitor temperature and humidity in compatible food-processing rooms, humid production areas and moisture-sensitive operations. Confirm hygiene and cleaning requirements separately.
Support humidity monitoring in suitable fermentation rooms and controlled production environments. Direct exposure to corrosive gases or aggressive cleaning agents requires compatibility review.
Measure conditions in compatible drying and humidification processes within the verified temperature and humidity limits of the selected probe assembly.
Provide temperature and RH data for suitable controlled-humidity test environments. Repeated condensation and extreme cycling must be evaluated before selection.
Support environmental monitoring in compatible manufacturing spaces. Any regulated or validated application requires project-specific documentation and qualification.
05 / PRODUCT OVERVIEWWatch the original product video to learn more about the HG808 transmitter family and available hardware configurations.
06 / TECHNICAL DATAThe following values are based on the supplied HG808-H specification table. Confirm the selected probe configuration and its applicable operating limits before ordering.
| Parameter | Specification |
|---|---|
| Temperature Measurement Range | −40 to +100°C |
| Humidity Measurement Range | 0–100% RH; source recommends below 95% RH |
| Temperature Accuracy | ±0.1°C at 20°C |
| Humidity Accuracy | ±2% RH at 20°C, 10–90% RH |
| Power Supply | 10–28 V DC |
| Power Consumption | Less than 0.5 W |
| Analog Output Options | 4–20 mA / 0–5 V / 0–10 V; select one type |
| RS485 Output | Temperature, RH, dew point and PPM |
| Communication Protocol | Modbus RTU |
| Baud Rate | 1200 / 2400 / 4800 / 9600 / 19200 / 115200 bps; default 9600 |
| Serial Format | 8 data bits, 1 stop bit, no parity |
| Resolution Options | 0.01 / 0.1°C; 0.01 / 0.1% RH |
| Fastest Acquisition Interval | 1 second |
| Pressure Rating | 16 bar, as listed; confirm applicable probe configuration |
| Working Environment | −20 to +60°C, 0–95% RH, non-condensing |
Measurement range is not the same as the permissible continuous operating environment. The original marketing text also states −40 to +190°C and continuous 95–98% RH capability; these claims require technical reconciliation with the datasheet.
07 / CONTROL SYSTEM INTEGRATIONHG808-H supports RS485 digital communication and analog output configurations. Choose the signal type according to your controller input and the required measurement variables.
RS485 Modbus RTURead temperature, humidity, dew point and PPM values through a compatible digital communication interface.
Analog Signal OptionsSelect 4–20 mA, 0–5 V or 0–10 V output according to the ordering configuration and controller requirements.
Wiring diagrams are from the original HG808 family page. Confirm the exact pinout, output configuration and power requirements for your ordered HG808-H model before installation.
08 / MODEL SELECTIONChoose a display-equipped model for local viewing or a non-display configuration for remote data acquisition. Review the original ordering charts for the available probe and signal combinations.
Confirm the final model code, probe type, output signal and high-humidity operating conditions with HENGKO before placing an order.
09 / TECHNICAL FAQThe product description targets high-moisture environments up to 98% RH, but the supplied specification table recommends below 95% RH and lists non-condensing working conditions. Confirm continuous exposure limits and supporting test data for your selected configuration.
No. High relative humidity does not necessarily mean liquid water is present on the sensor. Condensing conditions require separate evaluation of sensor protection, recovery and measurement performance.
Yes. The source specifications list RS485 Modbus RTU, with configurable baud rates including 9600 and 19200 bps.
The source lists calculated dew point as an RS485 output. Dew point accuracy depends on the underlying temperature and humidity measurements and the calculation method.
The supplied datasheet lists a temperature measurement range of −40 to +100°C and a working environment of −20 to +60°C. The higher temperature claim elsewhere on the original page requires verification for a specific probe assembly.
Provide the expected RH range, whether condensation occurs, process and ambient temperatures, mounting location, pressure, required output, probe length and estimated order quantity.
HENGKO / HIGH-HUMIDITY SENSOR SOLUTIONSShare your application conditions with HENGKO to review the suitable HG808-H configuration, probe design and available output options.
Include these details in your inquiry:Operating RH and temperature range, condensation exposure, process pressure, installation drawing, probe length, RS485 or analog output requirements, and order quantity.
Request HG808-H Technical Support & Quote
Email: ka@hengko.com