High-Precision Humidity Transmitter for Long-Term Use in 95%+ RH Environments – HG808-H

HENGKO HG808 SERIES / HIGH-HUMIDITY MONITORING

HG808-H High-Humidity Temperature & Humidity Transmitter

Designed for industrial environments where elevated relative humidity challenges conventional sensing equipment.

High moisture levels can make continuous temperature and humidity monitoring difficult, particularly in processing rooms, drying equipment and other humid industrial environments. The HENGKO HG808-H is designed for high-humidity monitoring applications, with industrial probe configurations and multiple signal output options.

Its combination of temperature, relative humidity and calculated dew-point data helps engineers monitor process conditions and identify conditions that may increase condensation risk.

Request HG808-H Quotation

98% RH
High-humidity design target*
±2% RH
At 20°C, 10–90% RH
RS485
Modbus RTU communication

*The stated high-humidity design target is not a verified continuous condensing-operation rating. Confirm the allowable operating envelope for the selected probe.

THE MEASUREMENT CHALLENGE

Why High-Humidity Measurement Requires Special Attention

As relative humidity approaches saturation, small temperature differences between the air, probe and surrounding surfaces can increase the likelihood of condensation. Water droplets on a sensing element may affect measurement recovery, accuracy and long-term reliability.

Persistent High Relative Humidity

Long periods of elevated humidity can place greater demands on sensor protection and maintenance.

Temperature and Moisture Fluctuations

Rapid changes in process conditions can influence sensor response and the risk of localized condensation.

Industrial Installation Constraints

Probe placement, cable routing, process temperature and maintenance access all affect measurement system design.

HG808-H DESIGN

Built Around High-Moisture Monitoring Requirements

High-Humidity-Oriented Probe Design

The HG808-H is positioned for humid industrial environments, including applications with relative humidity approaching the upper end of the measurement range. Continuous exposure and condensation tolerance should be confirmed for the selected probe.

Protective Metal Probe Housing

Available probe assemblies incorporate protective metal structures. The exact filter material, pore structure and environmental protection depend on the chosen configuration.

Industrial Electrical Protection

The original product information lists ESD and reverse-polarity protection, supporting integration into industrial monitoring systems.

MEASUREMENT & OUTPUT

Temperature, Relative Humidity and Dew-Point Monitoring

The HG808-H combines measured temperature and relative humidity with calculated moisture-related parameters for process monitoring and control system integration.

Temperature Measurement

Temperature data helps characterize the thermal conditions surrounding the sensor. The supplied technical table specifies a −40 to +100°C measurement range; other temperature claims require model-specific confirmation.

Relative Humidity Measurement

The technical table lists a 0–100% RH measurement range and recommends operation below 95% RH. The separate 95–98% RH durability claim needs a defined continuous operating condition.

Calculated Dew Point

Calculated dew-point temperature provides another way to interpret moisture conditions. Comparing dew point with surface temperature can help identify potential condensation conditions.

Analog and Digital Signals

The product supports RS485 Modbus RTU communication and analog output configurations for temperature and humidity, allowing integration with compatible PLC, DCS and SCADA systems.

TECHNICAL REFERENCE

HG808-H Technical Specifications

The following data follows the supplied product specification table. Some values should be confirmed for the HG808-H variant rather than assumed to apply to every HG808 probe.

Measurement Performance
Temperature Range −40 to +100°C (datasheet reference)
Humidity Range 0–100% RH; recommended below 95% RH
Temperature Accuracy ±0.1°C at 20°C
Humidity Accuracy ±2% RH at 20°C, 10–90% RH
Resolution Temperature: 0.01 / 0.1°C; RH: 0.01 / 0.1% RH
Electrical & Communication
Power Supply DC 10–28 V
Power Consumption Less than 0.5 W
Analog Output Temperature and RH; selectable 4–20 mA, 0–5 V or 0–10 V configuration
RS485 Modbus RTU Temperature, RH, dew point and PPM data
Baud Rate 1200 / 2400 / 4800 / 9600 / 19200 / 115200 bps; default 9600
Serial Format 8 data bits, no parity, 1 stop bit
Acquisition Interval Fastest listed: 1 second
Environmental & Installation
Electronics Operating Environment −20 to +60°C; 0–95% RH, non-condensing
Pressure Rating 16 bar listed; verify probe-specific suitability
Probe Families 0A/0B, 3A/3B, 5A/5B, 6A/6B listed in supplied table
Specification clarification: The supplied introduction claims operation up to 190°C and prolonged 95–98% RH exposure, while the technical table lists +100°C and recommends less than 95% RH. The validated HG808-H operating envelope should be confirmed before publishing stronger performance claims.

PROBE CONFIGURATION

Choose the Probe Geometry for Your Installation

HG808-series probe options include split and pipeline configurations. The selected probe should match the installation geometry, process conditions and service requirements.

Split-Type Probes

Allow the sensing probe to be positioned separately from the transmitter electronics, depending on the selected assembly.

Pipeline Probes

Designed for insertion into compatible pipe or duct measurement locations using the specified mounting arrangement.

Images illustrate HG808-series probe styles. Confirm which configurations are available specifically for HG808-H.

SYSTEM INTEGRATION

Connect HG808-H to PLC, SCADA or Monitoring Systems

Select the communication interface according to the receiving equipment. The analog configuration provides temperature and humidity signals, while RS485 Modbus RTU allows compatible systems to read multiple measurement values digitally.

RS485 Modbus RTU

Digital communication for temperature, relative humidity, calculated dew point and PPM values. Confirm register mapping, scaling and device address settings before integration.

Analog Signal Options

4–20 mA, 0–5 V and 0–10 V configurations are listed. The selected analog output type should be specified at ordering.

Wiring Reference Diagrams

Always follow the wiring diagram supplied with the exact purchased model. Wire colors and terminal assignments may differ by configuration.

ORDER CONFIGURATION

HG808-H Model Selection: Display and Non-Display Versions

The original product list separates HG808-H transmitters with local display from models without a display. Use the model charts below to identify the intended ordering configuration.

With Local Display

Without Local Display

When requesting a quotation, include the desired probe, display option, analog output type, RS485 requirements, cable length and estimated purchase quantity.

APPLICATIONS

High-Humidity Monitoring in Industrial Processes

The HG808-H is intended for industrial environments where humidity monitoring remains important during elevated moisture conditions. Application suitability depends on the actual temperature, humidity, condensation and chemical exposure.

Food and Beverage Processing

Monitor temperature and humidity in suitable processing rooms, conditioning areas and humid production environments where moisture variations affect process control.

Industrial Drying and Conditioning

Track changes in humidity and temperature during drying or conditioning operations within the selected probe's validated operating range.

Fermentation and Bioprocess Facilities

Monitor moisture conditions in compatible fermentation-related spaces and industrial environments, subject to cleaning and material compatibility requirements.

Pharmaceutical Production Environments

Provide environmental monitoring data for suitable manufacturing or utility areas. Qualification, calibration and regulatory compliance requirements must be assessed separately.

Chemical Processing Areas

Monitor temperature and humidity where moisture conditions are relevant to equipment or process operation. Exposure to corrosive vapors requires specific probe compatibility verification.

PRODUCT VIDEO

Explore the HG808 Transmitter Series

ENGINEERING FAQ

Frequently Asked Questions About HG808-H

Can HG808-H operate continuously at 98% RH?

The original description identifies 95–98% RH as a high-humidity design target. However, the specification table recommends below 95% RH. Continuous exposure limits, condensation tolerance and performance stability must be confirmed.

Is HG808-H suitable for steam or direct water spray?

High relative humidity does not automatically mean compatibility with saturated steam, liquid water immersion or direct spray. These conditions require separate protection and temperature verification.

Does HG808-H support Modbus RTU?

Yes. The supplied technical information lists RS485 Modbus RTU for reading temperature, humidity, dew point and PPM data.

Can I select a version with a display?

Yes. The supplied product list includes versions with and without a local display. Confirm the required probe and output combination when ordering.

How should the probe be installed in humid equipment?

Select a location representative of the process, avoid unnecessary liquid water accumulation, consider maintenance access and keep transmitter electronics within their specified ambient conditions.

HENGKO / HIGH-HUMIDITY SENSING

Discuss Your High-Humidity Monitoring Application

Share your temperature range, normal and peak RH, condensation conditions, probe installation method and output requirements. HENGKO can help review the appropriate HG808-H configuration.

Request Technical Support & Quote