High-Precision HPLC Column End Frit Filter

10 μm Sintered Stainless Steel | Ø4.8 × 1.53 mm

Compact sintered metal frit components for compatible chromatography column assemblies. Designed for OEM evaluation where controlled fluid passage, mechanical support and precise dimensional fit are essential.

10 μm Pore Grade Ø4.8 mm OEM Components

View Specifications Request a Quote

PORE GRADE
10 μm
DIAMETER
4.8 mm
THICKNESS
1.53 mm

01 / PRODUCT OVERVIEW

Sintered Metal Frit Components for HPLC Column Assemblies

HPLC column frits are porous components installed at designated locations within chromatography column assemblies. They provide a fluid passage while helping retain packing material when the selected pore structure is compatible with the stationary phase.

HENGKO offers compact sintered stainless steel components for chromatography equipment and OEM applications. This model features a listed 10 μm pore grade and a compact Ø4.8 × 1.53 mm format.

Important Selection Consideration

Frit pore size must be selected according to the chromatography column design and packing particle size. A 10 μm frit should not be assumed suitable for retaining conventional small-particle analytical HPLC packing without validation.

02 / TECHNICAL DATA

10 μm HPLC Column End Frit Specifications

The following specifications are based on the supplied product information. Additional performance parameters are available for review during engineering selection.

Parameter Specification
Product HPLC Column Endcap Frit Filter
Listed Pore Grade 10 μm
Outer Diameter 4.8 mm
Thickness / Height 1.53 mm
Metal Material Sintered stainless steel 316L (as described in source)
PEEK Option PEEK-related construction mentioned; exact assembly to be confirmed
Application Compatible chromatography column assemblies
Customization OEM drawing and specification review

Pressure rating, differential pressure, permeability, particle retention efficiency, surface finish and model-specific dimensional tolerances have not been provided. Request confirmed technical data before qualification.

03 / PRODUCT DESIGN

Compact Stainless Steel Frit for Precision Column Integration

The small disc geometry allows the frit to be integrated into compatible column end fittings and retaining structures. Accurate component dimensions and appropriate sealing are important to avoid bypass flow or mechanical interference.

Sintered Porous Structure

A bonded metal pore network provides fluid passage through the frit.

Compact Disc Format

The Ø4.8 × 1.53 mm dimensions support evaluation for compatible end fitting geometries.

316L Stainless Steel

A commonly used material for chromatography fluid-contact components, subject to solvent compatibility.

OEM Customization

Alternative geometry and pore specifications can be discussed based on customer drawings.

04 / CHROMATOGRAPHY FUNCTION

What Does an HPLC Column End Frit Do?

Column end frits are small but important components in liquid chromatography hardware. Their performance depends on pore structure, fit, cleanliness and compatibility with the complete column design.

01. Retain Compatible Column Packing

When correctly selected, a frit helps prevent stationary-phase particles from escaping the packed bed.

02. Allow Mobile Phase Flow

The porous structure permits liquid flow through the column end assembly.

03. Support Column End Assembly Design

The frit works together with the end fitting and sealing geometry to support the intended fluid path.

04. Help Maintain a Controlled Flow Path

Suitable pore structure and installation help minimize unwanted bypass or particle migration. Actual flow distribution and backpressure require testing.

05 / APPLICATION MATCHING

Applications for HPLC Frit Manufacturers & OEM Buyers

Chromatography Column Manufacturing

For column manufacturers evaluating porous metal components for end fitting and packing retention designs.

Custom Column Hardware

For custom chromatography hardware requiring specific frit dimensions and mechanical integration.

Laboratory Instrument OEM Components

For analytical equipment manufacturers seeking miniature porous stainless steel parts for validated fluid-path designs.

Replacement Frit Development

For customers developing compatible replacement components using a reference sample or approved engineering drawing.

06 / OEM ENGINEERING

Custom HPLC Column Frits for OEM Chromatography Hardware

HENGKO can review OEM requirements for miniature sintered metal components, including alternative dimensions and pore specifications. A reference drawing or sample is recommended for technical evaluation.

Customization Parameters

Dimensions: Diameter, thickness, fit and allowable tolerances.

Porous Media: Required pore grade and verified retention characteristics.

Materials: Stainless steel grade and any required polymer integration.

Performance: Flow rate, pressure drop, cleanliness and solvent compatibility.

Production: Prototype quantity, inspection criteria and annual demand.

07 / SELECTION CHECKLIST

How to Select a Suitable HPLC Column Frit

Before ordering a frit for a chromatography column, confirm the following engineering requirements.

Selection Factor Why It Matters
Pore Grade Must be appropriate for the packing particle size and retention requirements.
Diameter & Thickness Determine compatibility with the end fitting and sealing geometry.
Backpressure Excessive restriction may affect system operation.
Material Compatibility Frit material must suit the mobile phase and cleaning procedures.
Cleanliness Residual particles and extractables may interfere with analytical use.
Pressure Conditions The complete frit assembly must be qualified for the intended operating pressure.

08 / MANUFACTURING SUPPORT

HENGKO Sintered Metal Manufacturing Capabilities

HENGKO manufactures porous metal components for filtration and instrumentation applications. Our engineering team can review customer drawings and specifications for miniature sintered parts.

Certificate coverage and product-specific quality documentation should be verified for the intended procurement requirements.

09 / TECHNICAL FAQ

HPLC Column End Frit FAQ

What is the size of this HPLC column end frit?

The listed size is 4.8 mm in diameter and 1.53 mm in thickness, with a 10 μm pore grade.

Is a 10 μm frit suitable for every analytical HPLC column?

No. Frit selection depends on packing particle size, column construction and retention requirements. A 10 μm frit may not retain conventional fine analytical column packing.

Is the frit made from 316L stainless steel or PEEK?

The supplied description mentions sintered stainless steel 316L and PEEK. Confirm whether PEEK is part of a combined assembly or a separate material option.

Can this frit withstand high HPLC pressure?

The original product information describes high-pressure resistance but does not provide a tested rating. Pressure suitability must be confirmed for the complete installed assembly.

Can HENGKO manufacture custom frit sizes?

HENGKO can review customer drawings and requirements for customized sintered metal frit components.

What information should I send for a quotation?

Please provide diameter, thickness, pore grade, material, application, pressure conditions, required quantity and any available engineering drawing.

10 / RELATED COMPONENTS

Related Sintered Metal Filter Components

Explore alternative porous metal components for filtration and custom instrumentation applications.

Sintered Stainless Steel Filter Discs

Porous metal disc components for compatible filtration assemblies.

Multilayer Stainless Steel Mesh Filters

Alternative metal filtration media for application-specific engineering evaluation.

HENGKO / CHROMATOGRAPHY OEM COMPONENTS

Looking for a Precision HPLC Column Frit Supplier?

Contact HENGKO for 10 μm Ø4.8 mm sintered metal frit specifications, sample availability and OEM customization options.

Recommended RFQ Details

Frit diameter, thickness, pore grade, column type, packing particle size, operating pressure, solvent system, required quantity and technical drawing.

Request Samples & OEM Quotation

Email: ka@hengko.com


  • High Precision Stainless Steel HPLC Column Endcap Frit Filter for Analytical Separation Systems Related Video: