Humidity Sensor Probe with Dew Point , -30~80°C,0~100%RH RS485/MODBUS-RTU HT-800

 

HENGKO / INDUSTRIAL SENSOR SOLUTIONS

HT-800 RS485 Temperature & Humidity Sensor Probe

Digital Temperature, Relative Humidity & Calculated Dew Point

Compact industrial humidity sensor probe with RS485 / Modbus-RTU communication for environmental monitoring, industrial equipment and OEM control system integration.

RS485 / Modbus-RTU 0–100%RH Dew Point Data

View Specifications Request a Quote

HUMIDITY RANGE 0–100%RH RH ACCURACY ±2%RH* DIGITAL OUTPUT RS485

*Humidity accuracy listed at 25°C in the original product specifications.

01 / PRODUCT OVERVIEW

Industrial Digital Humidity Probe with Modbus-RTU Communication

The HENGKO HT-800 series is a miniature digital temperature and humidity sensor probe designed for industrial monitoring and equipment integration.

The original product information describes an integrated Sensirion RHT-series temperature and humidity sensing component, providing temperature and relative humidity measurements with calculated dew point data.

Its RS485 / Modbus-RTU communication interface enables connection to compatible PLCs, DCS systems, industrial gateways and data acquisition equipment.

One Digital Probe. Three Environmental Parameters.

Temperature measurement + Relative humidity measurement + Calculated dew point output.

02 / KEY FEATURES

Designed for Digital Environmental Monitoring

Integrated Sensing

Miniature temperature and humidity sensing component for compact installations.

Digital RS485 Output

Modbus-RTU interface for compatible industrial monitoring systems.

Porous Metal Protection

Stainless steel protective structure designed to permit ambient air exchange.

OEM-Friendly Construction

Threaded mounting and shielded wiring for industrial equipment integration.

03 / SENSOR CONSTRUCTION

HT-800 Sensor Probe Construction & Component Details

The HT-800 combines a miniature sensing component, stainless steel threaded mounting connection and shielded electrical cable in a compact probe assembly.

COMPONENT 01

Built-in Sensing Element

Integrated temperature and humidity sensing element for digital environmental measurement.

Measures: Temperature & RH Calculated Data: Dew Point Interface: RS485 / Modbus-RTU T + RH Integrated sensing

SS Threaded mounting COMPONENT 02

Stainless Steel Threaded Connection

Metal threaded connection for mounting the probe into compatible equipment and measurement assemblies.

Material: Stainless Steel Purpose: Probe Installation Selection: Verify Thread Size

COMPONENT 03

Four-Core Shielded Cable

Four-core shielded cable for power and RS485 signal transmission. Correct wiring and shielding help reduce electrical interference.

Type: Four-Core Shielded Standard Length: 3 m Function: Power & Communication 4-Core Shielded signal cable

Mechanical Dimensions & Installation Reference

Refer to the dimensional drawing for the sensor assembly, mounting geometry and installation clearance.

04 / TECHNICAL SPECIFICATIONS

HT-800 Temperature & Humidity Sensor Specifications

Reference specifications from the original product information. Confirm the current datasheet before final selection.

Parameter Specification
Model HT-800
Temperature Range −20 to +60°C (original table)
Humidity Range 0–100%RH
Temperature Accuracy ±0.2°C (stated at 0–90°C; confirm)
Humidity Accuracy ±2%RH at 25°C
Dew Point Calculated output (original table: 0–60°C)
Power Supply DC 4.5–12V (original table; confirm)
Power Consumption Less than 0.1 W
Response Time 10 s at 1 m/s airflow (criterion unspecified)
Communication RS485 / Modbus-RTU
Baud Rates 1200 / 2400 / 4800 / 9600 / 19200 bps
Default Baud Rate 9600 bps
Serial Format 8 data bits, 1 stop bit, no parity
Long-Term Stability RH <1%RH/year; temperature <0.1°C/year (stated)
Cable Four-core shielded, 3 m standard
Ingress Protection Original text mentions IP65–IP67; verify exact model rating
Important Specification Note

Original product text lists DC 4.5–24V, while the specification table lists DC 4.5–12V. Confirm the correct operating voltage before installation.

05 / RS485 COMMUNICATION

RS485 / Modbus-RTU Integration for PLC & Data Acquisition

The HT-800 uses RS485 communication with the Modbus-RTU protocol to transmit digital temperature, humidity and calculated dew point data.

HT-800 Sensor Probe RS485 A/B + DC Power PLC / DCS / Gateway / Data Logger

Electrical Connection Reference

Integration Checklist

Verify supply voltage, RS485 A/B polarity, communication address, baud rate, cable shielding and Modbus register definitions before commissioning.

06 / APPLICATIONS

Where Can the HT-800 Humidity Probe Be Used?

The HT-800 is intended for temperature and humidity measurement in compatible industrial monitoring and OEM systems.

Industrial Equipment Monitoring

Monitor environmental conditions in suitable equipment enclosures and machinery.

Factory Environmental Monitoring

Collect temperature and relative humidity data for industrial monitoring systems.

OEM Control & Automation

Integrate sensor measurements with compatible PLC-based equipment.

Remote Environmental Data Collection

Transmit measurement data to compatible industrial gateways and monitoring software.

07 / DEW POINT DATA

Calculated Dew Point for Condensation Awareness

Dew point is the temperature at which air reaches saturation when cooled at constant pressure.

The HT-800 calculates dew point from temperature and relative humidity measurements, supporting environmental monitoring and condensation risk assessment.

Calculated Dew Point Output

HT-800 is a temperature and humidity probe with calculated dew point output, rather than a dedicated low-dew-point transmitter for very dry process gases.

08 / INSTALLATION GUIDANCE

Installation Considerations for Reliable Measurements

Air Exposure: Install the probe where it can sample representative ambient conditions.

Condensation: Avoid prolonged water accumulation unless the installation is approved for those conditions.

Electrical Connections: Follow the correct supply voltage, wiring and shielding requirements.

Outdoor Use: Confirm the exact ingress protection rating for the supplied model.

09 / OEM SUPPORT

OEM Humidity Sensor Probe Integration Support

HENGKO can discuss integration requirements for industrial temperature and humidity measurement systems, including mounting geometry, cable length and communication settings.

What to Include in Your OEM Enquiry

Measurement range, required accuracy, supply voltage, installation environment, cable length, Modbus communication requirements, sample quantity and estimated annual volume.

10 / FREQUENTLY ASKED QUESTIONS

HT-800 Temperature & Humidity Sensor FAQ

What does the HT-800 measure?

It measures temperature and relative humidity and provides calculated dew point data.

Does the HT-800 support Modbus-RTU?

Yes. The product uses RS485 communication with the Modbus-RTU protocol.

Can it be connected to a PLC?

Yes, provided the PLC or gateway supports the required RS485 communication settings and Modbus register mapping.

What is the default baud rate?

The original specifications list 9600 bps as the default baud rate.

Does the probe directly measure dew point?

Dew point is calculated from measured temperature and relative humidity.

Can the HT-800 be installed outdoors?

Suitability depends on the specific model, its confirmed IP rating and installation conditions.

Can the cable length be customized?

The original information describes a standard 3 m cable and states that longer lengths may be available. Confirm requirements with HENGKO.

11 / RELATED SOLUTIONS

Related Industrial Humidity Sensor Solutions

Weather-Resistant Humidity Sensor Probe

Alternative sensor construction for environmental monitoring requirements.

Porous Stainless Steel Sensor Housing

Protective porous metal housing for compatible sensor assemblies.

Industrial Dew Point Measurement Instruments

Alternative instruments for different dew point measurement requirements.

HENGKO / TECHNICAL SUPPORT & QUOTATION

Need an RS485 Humidity Probe for Your Equipment?

Contact HENGKO to confirm the latest HT-800 specifications, request Modbus communication documentation or discuss OEM integration.

Request HT-800 Quotation

Email: ka@hengko.com