HENGKO semiconductor vent diffuser filters combine a sintered 316L stainless steel porous element with a gas-distribution design for controlled venting and particle management in vacuum process chambers. Available in disc and cartridge configurations with ISO NW vacuum flange options, these components support equipment integration where clean gas delivery and reduced localized gas jets are important.
| Parameter | Original Datasheet Value | Engineering Note |
|---|---|---|
| Filter medium | 316L sintered stainless steel | As supplied in original product information |
| Housing | 316L stainless steel | Confirm wetted material and weld details |
| Inner surface roughness | Ra ≤ 32 μm | Verify measurement surface and finish requirement |
| Filtration rating | Original claim: ≥ 0.003 μm | Requires clarification of particle size, removal efficiency and test method |
| Maximum inlet pressure | 4 bar | Confirm whether gauge or absolute pressure |
| Maximum operating differential pressure | 5 bar | Confirm allowable pressure direction and operating envelope |
| Maximum operating temperature | 400 °C | Confirm assembly, seal and flange temperature limits |
| Downstream cleanliness | ≤ 0.03 particles/L at > 0.01 μm, rated flow | Confirm test gas, method, upstream challenge and test report |
Technical values above reproduce the supplied product data and are not independently verified. Confirm the latest approved drawing and test report before using them as contractual performance limits.
Disc-type designs offer a compact porous surface for vacuum chamber vent-gas distribution. Select the appropriate ISO NW flange and confirm available installation clearance.
| Product Model | Inlet Specification | Outlet Specification | Total Length (A) | Filter Element OD (φB) | Housing OD (φC) |
|---|---|---|---|---|---|
| Z01B-00639 | 1/4’’ | ISO NW40 Vacuum Flange | 42mm (1.64’’) | Φ39mm (1.53’’) | Φ55mm (2.16’’) |
| Z01B-00695 | 1/4’’ | ISO NW50 Vacuum Flange | 42mm (1.64’’) | Φ52mm (2.05’’) | Φ75mm (2.95’’) |
Cartridge-type elements provide an extended porous element length for configurations that require a different gas distribution area or installation geometry.
| Product Model | Inlet Specification | Outlet Specification | Total Length (A) | Filter Element OD (φB) | Housing OD (φC) | Filter Tube Length (D) |
|---|---|---|---|---|---|---|
| Z01B-00697 | 1/4’’ | ISO NW16 Vacuum Flange | 81mm (3.18’’) | Φ16mm (0.64’’) | Φ30mm (1.18’’) | 44mm (1.74’’) |
| Z01B-00501 | 1/4’’ | ISO NW16 Vacuum Flange | 104mm (4.08’’) | Φ16mm (0.64’’) | Φ30mm (1.18’’) | 67mm (2.64’’) |
| Z01B-00698 | 1/4’’ | ISO NW16 Vacuum Flange | 135mm (5.30’’) | Φ16mm (0.64’’) | Φ30mm (1.18’’) | 98mm (3.86’’) |
| Z01B-00699 | 1/4’’ | ISO NW25 Vacuum Flange | 81mm (3.18’’) | Φ16mm (0.64’’) | Φ40mm (1.58’’) | 44mm (1.74’’) |
| Z01B-00700 | 1/4’’ | ISO NW25 Vacuum Flange | 104mm (4.08’’) | Φ16mm (0.64’’) | Φ40mm (1.58’’) | 67mm (2.64’’) |
| Z01B-00701 | 1/4’’ | ISO NW40 Vacuum Flange | 104mm (4.08’’) | Φ16mm (0.64’’) | Φ55mm (2.16’’) | 67mm (2.64’’) |
Specify the vent gas and purity, chamber volume, starting and final chamber pressure, target venting time, maximum allowable pressure drop, flow profile, flange size, available installation space, temperature and required particle cleanliness. These factors determine whether a disc or cartridge configuration is appropriate.
HENGKO can review drawings and application requirements for custom dimensions, porous element geometry and connection interfaces. Request available inspection, helium leak test, cleanliness and packaging documentation for the specific part number. Do not assume a cleanroom class or 100% testing protocol without written confirmation.
It is a porous gas-distribution and filtration component used in vacuum chamber venting systems to moderate incoming gas jets and help manage particles.
A diffuser distributes gas across a porous area; a restrictor primarily sets or limits flow. Actual venting performance depends on the entire gas path and pressure conditions.
Not automatically. They differ in dimensions and porous geometry. Compare flange interfaces, flow requirements, pressure drop and chamber clearance.
Nitrogen venting is a potential application, subject to gas compatibility, cleanliness requirements and validated operating conditions.
The source datasheet includes a 0.003 μm claim, but does not define removal efficiency or test method. Request validated performance data before specifying this rating.
Send the target part number or drawing, flange size, gas type, flow and pressure conditions, temperature, required cleanliness level, quantity and delivery destination.
Send your chamber application, required flange size, flow and pressure conditions, model number or technical drawing, and estimated order quantity. Our team can review a suitable disc, cartridge or custom configuration.