Compact stainless steel filtration assemblies for semiconductor equipment, high-purity gas distribution and precision instrumentation.
When particles enter a precision gas line, they can interfere with regulators, valves, mass flow controllers and sensitive downstream equipment. HENGKO offers all-welded inline filter configurations that OEM engineers can evaluate for particle filtration within compact tubing and fluid-control systems.
Discuss Your OEM Project View Filter Models
FILTER DESIGN All-Welded Inline ELEMENT OPTIONS Sintered / Pleated INTERFACES Tube / NPT / Face Seal 01 / SYSTEM REQUIREMENTS
In semiconductor manufacturing equipment, analytical instruments and precision gas-control assemblies, contamination can originate from tubing, assembly operations, upstream components or the process itself.
An inline filter creates a defined particulate filtration point inside the flow path. The correct design depends on the gas or liquid, particle retention requirement, flow rate, differential pressure and connection geometry.
What OEM engineers need to balanceParticle retention, flow capacity, pressure drop, installation length, leak integrity, wetted-material compatibility and repeatability across production batches.
02 / TARGET SYSTEMSParticle filtration in compatible gas cabinets, gas panels and equipment-level gas lines. Applications requiring UHP performance need separately verified cleanliness, particle efficiency and leak specifications.
APPLICATION 02Inline particulate protection in compatible nitrogen, argon and other specialty-gas distribution systems. Gas purity classification and material compatibility must be confirmed.
APPLICATION 03Upstream particle filtration for compatible MFCs, pressure regulators, control valves and other sensitive flow-management components.
APPLICATION 04Compact filtration for gas chromatography supply lines, sampling instruments and suitable small-volume gas or liquid systems.
03 / COMPONENT CONFIGURATIONHENGKO's original inline filter range includes all-welded construction, multiple filter element grades and several connection formats. These options provide a starting point for standard model selection or OEM design review.
A welded filter housing offers a compact, non-disassemblable body arrangement. Actual leak integrity must be established through appropriate inspection and testing rather than assumed from construction alone.
The inline form factor is suited to equipment layouts where filtration must be incorporated directly into a short tubing or process-fluid connection.
Compression fittings, NPT threads and male face seal interfaces are listed. The exact connection must match the equipment's tubing, mating hardware and assembly requirements.
The source product information references reverse-flow cleaning. Cleaning feasibility and reuse limits depend on filter media, trapped contaminants and the validated service procedure.
04 / FILTRATION MEDIAFilter media selection should begin with the required particle retention and allowable pressure drop. The original product range includes sintered metal and pleated mesh configurations.
SINTERED METALA rigid porous element option for selected configurations. Evaluate its particle retention, pressure drop and cleanliness characteristics against the actual system requirements.
PLEATED MESHPleated mesh configurations provide alternative nominal pore grades. Their effective filtration behavior must be evaluated using relevant test data.
*The source introduction also states 2.7 μm and 15 μm. Confirm whether 2.7 μm is one grade or a typographical error before finalizing the catalogue.
05 / OEM PROJECT PLANNINGFor equipment manufacturers, selecting an inline filter is not only about the nominal pore grade. The assembly must also fit the gas line, operate within the process limits and meet the project's quality documentation needs.
01 Define the Fluid and ContaminationIdentify the gas or liquid, particulate sources, purity target and compatibility constraints.
02 Set the Operating EnvelopeSpecify working pressure, temperature, flow rate and maximum acceptable differential pressure.
03 Select Media and ConnectionsCompare sintered and pleated media, then confirm compression, NPT or face seal interfaces.
04 Review Drawings and Test RequirementsConfirm envelope dimensions, material specifications and any required particle, cleanliness or leak testing.
05 Plan Sampling and Production QuantitiesShare prototype quantity, expected annual demand and inspection requirements for an OEM feasibility review.
06 / MODEL REFERENCEUse these original catalogue references as a starting point for selecting the correct connection and nominal pore grade. The listed codes are basic part numbers or prefixes, not necessarily complete ordering numbers.
| Connection | Size | Pore μm | Part Number | Orifice | Length A |
|---|---|---|---|---|---|
| Compression | 1/4" | 0.5 | HG-SS-4FWS- | 4.75 mm | 53.1 mm |
| Compression | 1/4" | 2 / 7 / 15 | HG-SS-4FW- | 4.75 mm | 54.6 mm |
| Compression | 6 mm | 0.5 | HG-SS-6FWS-MM- | 4.75 mm | 54.1 mm |
| Compression | 6 mm | 2 / 7 / 15 | HG-SS-6FW-MM- | 4.75 mm | 54.6 mm |
| Female NPT | 1/4" | 2 / 7 / 15 | HG-SS-4FW4- | 11.5 mm | 39.9 mm |
| Male NPT | 1/4" | 2 / 7 / 15 | HG-SS-4FW2- | 7.14 mm | 48.0 mm |
| Male/Female NPT | 1/4" | 2 / 7 / 15 | HG-SS-4FW5- | 7.14 mm | 43.7 mm |
| Male Face Seal | 1/4" | 0.5 | HG-SS-4FWS | 4.75 mm | 50.8 mm |
| Male Face Seal | 1/4" | 2 / 7 / 15 | HG-SS-4FW | 4.75 mm | 51.8 mm |
Dimensions are catalogue references from the original page. Verify final drawings, connection details and complete part numbers before ordering.
07 / HIGH-PURITY GAS CONSIDERATIONSA stainless steel housing and a small nominal pore size are not sufficient evidence of semiconductor-grade ultra-high-purity performance. OEM qualification should address the following requirements according to the intended gas system.
Particle Retention PerformanceRequest validated efficiency or particle retention data at the relevant particle sizes and operating conditions.
Leak IntegrityDefine the required leak test method, acceptance limit and test conditions for the complete filter assembly.
Cleanliness and Surface ConditionConfirm cleaning, packaging, particle shedding, surface finish and any required contamination control procedures.
Materials and Gas CompatibilityVerify the wetted-material specification, operating pressure, temperature and compatibility with the actual gas chemistry.
The supplied product information does not establish that all listed models meet UHP semiconductor specifications. Request application-specific documentation and testing requirements during engineering review.
08 / OEM ENGINEERING FAQThey may be evaluated for compatible semiconductor equipment gas lines. Actual use depends on the required particle efficiency, gas compatibility, cleanliness, leak integrity and qualification documentation.
A UHP gas filter typically requires more stringent verified contamination control and qualification criteria. An industrial filter should not be treated as UHP-rated without supporting test evidence.
Yes. The original catalogue lists 1/4-inch compression, 6 mm compression and 1/4-inch male face seal configurations, alongside several NPT options.
No. Nominal pore size and absolute retention efficiency are different specifications. Request the relevant test method and efficiency data.
OEM customers can submit drawings and operating requirements for feasibility review. Available modifications, prototype quantities and production terms are subject to technical and commercial confirmation.
HENGKO / OEM FILTER ENGINEERINGWhether you are designing a semiconductor gas panel, precision instrumentation system or compact liquid circuit, HENGKO can review your filtration requirements and suitable standard or custom configurations.
For a faster technical review, send: fluid type, filtration requirement, flow rate, operating pressure, temperature, connection drawing and expected quantity.
Send Your OEM Filter Requirements
Email: ka@hengko.com