Economy Humidity and Temperature Transmitter with RS485 Output HG803

HENGKO HG803 SERIES

Industrial Temperature and Humidity Transmitter

Reliable temperature and relative humidity monitoring for HVAC, air ducts, warehouses, industrial processes and equipment integration.

The HENGKO HG803 Series is a flexible industrial temperature and humidity transmitter platform designed around different sensing positions, installation methods and control-system requirements. Select from remote, replaceable, integrated and air-duct probe configurations.

RS485 Modbus-RTU 4–20 mA 0–5 V / 0–10 V Multiple Probe Options Up to 20 m Cable

Measurement Temperature + Relative Humidity
Humidity Range 0–100% RH
Digital Output RS485 Modbus-RTU
Analog Output 4–20 mA / 0–5 V / 0–10 V
Configurations Split / Replaceable / Integrated / Air Duct

WHY HG803

One Transmitter Platform. Multiple Sensing Configurations.

 

Industrial temperature and humidity monitoring rarely uses one installation method. HG803 is designed as a flexible transmitter platform that can be configured for remote sensing, replaceable probes, integrated installation or direct air-duct measurement.

01

Flexible Probe Options

Choose split, replaceable, integrated or air-duct probe configurations according to sensing position, installation space and maintenance requirements.

02

Industrial Signal Outputs

RS485 Modbus-RTU is available for digital system integration, with 4–20 mA, 0–5 V and 0–10 V analog output configurations.

03

Remote Measurement

Remote probe configurations allow the sensing element to be positioned away from the transmitter, with cable lengths available up to approximately 20 meters.

04

Industrial Reliability

Industrial-grade ESD protection, reverse-power protection and multiple probe structures support reliable operation in demanding monitoring environments.

HG803 CONFIGURATIONS

Four Probe Configurations for Different Installations

 

Choose the probe structure according to sensing position, maintenance requirements and installation method.

HG803 SPLIT PROBE

Split / Remote Probe

The sensing probe is separated from the transmitter, allowing temperature and humidity to be measured at a remote location while the transmitter remains in an accessible position.

✓Remote sensing point

✓Multiple probe structures

✓Sensor cable up to approximately 20 m

✓Flexible installation and maintenance

HG803 REPLACEABLE PROBE

Detachable & Replaceable Probe

The sensing head can be replaced independently without replacing the complete transmitter or cable assembly, simplifying field maintenance.

✓Field-replaceable sensing head

✓Lower maintenance cost

✓Reduced equipment downtime

✓Suitable for OEM equipment integration

HG803 INTEGRATED PROBE

Integrated Probe Type

The sensing probe is directly integrated with the transmitter for compact installation and general environmental monitoring.

✓Compact integrated design

✓Simple installation

✓Less external wiring

✓Suitable for indoor environments

HG803 AIR DUCT TYPE

Air Duct Probe

Extended probe structures position the sensing element directly inside ventilation ducts, air handling systems and process air streams.

✓Extended stainless-steel probe

✓Threaded installation options

✓Flange installation options

✓HVAC and air-duct monitoring

PROBE OPTIONS

Multiple Probe Designs for Different Installation Conditions

 

HG803 supports multiple sensing probe structures, allowing the sensing element to be positioned where temperature and humidity actually need to be measured.

✓ Standard Probe — general industrial environmental monitoring

✓ Flanged Long Probe — deep insertion into ducts or process equipment

✓ Flanged Short Probe — fixed duct or chamber installation

✓ Threaded Probe — threaded process connection

✓ Plastic Housing Probe — general-purpose environmental sensing

✓ Replaceable Probe — maintenance-friendly applications

TECHNICAL DATA

HG803 Technical Specifications

 

Actual specifications depend on probe type and selected configuration. The table below summarizes the main capabilities of the HG803 platform.

Measured Parameters Temperature and Relative Humidity
Temperature Range Split stainless-steel probe configurations: approximately −40 to +120°C.
Plastic remote / replaceable probe configurations: approximately −40 to +100°C.
Air-duct configurations: approximately −40 to +80°C.
Integrated plastic sensor housing: approximately −20 to +60°C.
Humidity Range 0–100% RH
Temperature Accuracy ±0.3°C @ 25°C typical; higher-accuracy configurations available
Humidity Accuracy ±3% RH typical @ 60% RH, 25°C; higher-accuracy options available
Temperature Long-Term Stability ≤0.1°C/year
Humidity Long-Term Stability ≤1% RH/year
Digital Output RS485 Modbus-RTU
Analog Output Options 4–20 mA / 0–5 V / 0–10 V
Baud Rate 1200 / 2400 / 4800 / 9600 / 19200 / 115200 bps; default 9600 bps
Supply Voltage 10–30 VDC
Transmitter Operating Environment Approximately −20 to +60°C, 0–95% RH, non-condensing
Probe Cable Remote cable configurations available up to approximately 20 m
Protection Features Industrial-grade ESD protection and reverse-power protection
Protocol / Reading Supports single-register and multiple-register reading
Temperature Unit °C standard; °F customization available

Configuration note: Temperature range, enclosure protection and probe construction vary according to the selected HG803 probe configuration. Contact HENGKO with your operating temperature, humidity range, installation method and output requirement for final model selection.

SYSTEM INTEGRATION

Connect Directly to Industrial Control Systems

 

HG803 is designed for both standalone environmental monitoring and integration into automated industrial systems.

✓PLC

✓Industrial control host

✓Building Management System (BMS)

✓Data acquisition system

✓Digital display meter

✓Environmental monitoring platform

Available Signal Configurations

RS485 Modbus-RTU digital communication
4–20 mA Temperature + humidity analog output
0–5 V Voltage output configuration
0–10 V Voltage output configuration
Hybrid Analog output + RS485 configurations available

APPLICATIONS

Built for Industrial Temperature & Humidity Monitoring

From warehouses to air ducts, HG803 can be configured around the actual installation environment rather than forcing one sensor structure to fit every application.

HVAC & Air Ducts

Monitor supply air, return air and environmental conditions inside HVAC ducts and ventilation systems.

Warehouses & Storage

Continuous temperature and humidity monitoring for warehouses, storage rooms and distribution facilities.

Grain & Agriculture

Environmental monitoring for grain storage, greenhouses and agricultural facilities.

Clean Rooms & Laboratories

Monitor controlled environments where temperature and humidity stability are important to processes and product quality.

Industrial Processes

Suitable for process equipment, industrial rooms, air handling systems and environmental monitoring networks.

Rail & Infrastructure

Remote environmental monitoring for tunnels, rail systems, equipment rooms and infrastructure applications.

Communication Rooms

Monitor temperature and humidity around servers, communication equipment and electrical infrastructure.

Pharmaceutical Facilities

Environmental sensing for pharmaceutical production, storage and controlled processing areas.

OEM Equipment

Flexible probe structures and industrial outputs make HG803 suitable for integration into OEM equipment and monitoring systems.

MODEL SELECTION

Which HG803 Configuration Should You Choose?

Installation RequirementRecommended Configuration
General room / warehouse monitoring HG803 Integrated Probe
Sensor must be installed away from transmitter HG803 Split Probe
Sensor requires frequent replacement or maintenance HG803 Replaceable Probe
HVAC duct / ventilation system HG803 Air Duct Type
Deep insertion into duct or chamber Flanged Long Probe
Fixed threaded process connection Threaded Probe
PLC / BMS digital communication RS485 Modbus-RTU
Traditional industrial analog input 4–20 mA

OEM & CUSTOMIZATION

Need a Different Probe Length, Connection or Output?

HG803 can be configured around your equipment and installation environment. HENGKO supports industrial customers, system integrators and equipment manufacturers with customized sensing solutions.

✓Custom probe length

✓Remote probe cable length

✓Threaded process connections

✓Flange mounting

✓Replaceable probe design

✓RS485 Modbus-RTU

✓4–20 mA / voltage outputs

✓Temperature unit customization

✓OEM equipment integration

FAQ

HG803 Temperature & Humidity Transmitter FAQ

Does HG803 support RS485 Modbus?

Yes. HG803 supports RS485 communication using the Modbus-RTU protocol, making it suitable for PLC, BMS and industrial monitoring systems.

Can HG803 provide a 4–20 mA output?

Yes. Depending on configuration, HG803 can provide 4–20 mA, 0–5 V or 0–10 V analog outputs in addition to RS485 communication.

Can the temperature and humidity probe be replaced?

Yes. The HG803 Series includes a detachable and replaceable probe configuration. The sensing head can be replaced independently, helping reduce maintenance cost and downtime.

Can HG803 be installed inside an HVAC duct?

Yes. The HG803 Air Duct configuration is designed for duct and pipeline monitoring. Threaded, flange and extended probe installation options are available.

How long can the remote probe cable be?

Selected split-probe configurations can support remote sensor cables up to approximately 20 meters. Final cable length should be confirmed according to the selected probe and signal configuration.

What temperature range does HG803 support?

The temperature range depends on the selected sensing probe. Split stainless-steel probe configurations can reach approximately −40 to +120°C, while integrated, replaceable and air-duct configurations have different operating ranges.

Which HG803 probe should I choose?

The correct probe depends on your installation method, operating temperature, humidity range, required insertion depth, process connection and maintenance requirements. Send HENGKO your application conditions and we can recommend the appropriate configuration.

NEED HELP SELECTING A SENSOR?

Tell Us Your Temperature & Humidity Monitoring Requirements

Send us your temperature range, humidity range, installation method, probe length, process connection, cable length and required output signal. Our engineers will recommend the appropriate HG803 configuration.

Please provide:

✓ Temperature range

✓ Humidity range

✓ Installation environment

✓ Probe / insertion length

✓ Thread or flange connection

✓ Cable length

✓ RS485 / 4–20 mA / voltage output

Request a Quote

 

 

Can't find a product that meets your needs? Contact our sales staff for OEM/ODM customization services!